Abstract
Background
The range of an ablation zone (AZ) plays a crucial role in the treatment effect of microwave ablation (MWA). The aim of this study was to analyze the factors influencing the AZ range.
Methods
Fourteen factors in four areas were included: patient-related factors (sex, age), disease-related factors (tumor location, liver cirrhosis), serological factors (ALT, AST, total protein, albumin, total bilirubin, direct bilirubin, and platelets), and MWA parameters (ablation time, power, and needle type). Multiple sequence MRI was used to delineate AZ by three radiologists using 3D Slicer. MATLAB was used to calculate the AZ length, width, and area of the largest section. Linear regression analysis was used to analyze influencing factors. Moreover, a subgroup analysis was conducted for patients with viral hepatitis.
Result
220 patients with 290 tumors were included between 2010–2021. In addition to MWA parameters, cirrhosis and tumor location were significant factors that influenced AZ (p < 0.001). The standardized coefficient (beta) of cirrhosis (cirrhosis vs. non-cirrhosis) was positive, which meant cirrhosis would lead to a decrease in AZ range. The beta of tumor location (near the hepatic hilar zone, intermediate zone, and periphery zone) was negative, indicating that AZ range decreased as the tumor location approached the hepatic hilum. For viral hepatitis patients, Fibrosis 4 (FIB4) score was a significant factor influencing AZ (p < 0.001), and the beta was negative, indicating that AZ range decreased as FIB4 increased.
Conclusion
Liver cirrhosis, tumor location, and FIB4 affect the AZ range and should be considered when planning MWA parameters.
Disclosure statement
None of the authors have a conflict of interest to disclose.