Effects of Subchronic Exposures to Concentrated Ambient Particles (CAPs) in Mice: II. The Design of a CAPs Exposure System for Biometric Telemetry Monitoring

, , , , &
Pages 189-197 | Received 06 Jul 2004, Accepted 05 Aug 2004, Published online: 06 Oct 2008
 

Abstract

We modified, assembled, tested, and validated the versatile aerosol concentration enrichment system (VACES) developed by Citation for use in a subchronic experiment that involved exposures of mice in vivo and of respiratory epithelial cells in vitro to concentrated ambient particles (CAPs). Since the labor-intensive nose-only exposure regimen is not an option in a long-term experiment, a whole-body exposure mouse chamber was designed specifically for use with the VACES. The exposure system consists of a stainless-steel (SS) tub with 32 cubicles (1 mouse per cubicle) separated by perforated SS sheets. The tops of these cubicles are covered with perforated plastic sheets to allow telemetry monitoring during the exposure. In each exposure chamber, perforated aluminum tubes are used to distribute CAPs evenly (within 2% difference) throughout the exposure chamber. The exhaust consists of perforated aluminum tubes covered with a urine shield. The modification to the original design of the VACES facilitated the operation of the system in a subchronic study. Mass flow controllers maintain a constant flow rate into the exposure chambers. For a sham control exposure, the identical system is used, except that a HEPA filter at the inlet to the VACES removes 98% of ambient particles. The entire system allows for simultaneous exposure of 64 mice to CAPs, with an equal number of sham-exposed mice as controls. Telemetry receivers have been modified so that 16 mice per group with electrocardiograph (EKG) transmitters can be monitored during exposure. Furthermore, a BioSampler is used to collect CAPs (one sample per day) for the in vitro exposures. In this article, the assessments of flow and particle distribution of the exposure chamber as well as the performance of the system during the subchronic exposure experiment are described.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.