79
Views
0
CrossRef citations to date
0
Altmetric
Original Contributions

Effectiveness of a Novel Rapid Infusion Device and Clinician Education for Early Fluid Therapy by Emergency Medical Services in Sepsis Patients: A Pre-Post Observational Study

ORCID Icon, , , , , , , , , & show all
Received 16 Jun 2023, Accepted 17 Nov 2023, Published online: 11 Dec 2023
 

Abstract

Objective

Emergency medical services (EMS) clinicians are tasked with early fluid resuscitation for patients with sepsis. Traditional methods for prehospital fluid delivery are limited in speed and ease-of-use. We conducted a comparative effectiveness study of a novel rapid infusion device for prehospital fluid delivery in suspected sepsis patients.

Methods

This pre-post observational study evaluated a hand-operated, rapid infusion device in a single large EMS system from July 2021-July 2022. Prior to device deployment, EMS clinicians completed didactic and simulation-based device training. Data were extracted from the EMS electronic health record. Eligible patients included adults with suspected sepsis treated by EMS with intravenous fluids. The primary outcome was the proportion of patients receiving goal fluid volume (at least 500 mL) prior to hospital arrival. Secondary outcomes included in-hospital mortality, disposition, and length of stay. Multivariable logistic regression was used to compare outcomes between 6-month pre- and post-implementation periods (July-December 2021 and February-July 2022, respectively), adjusting for patient demographics, abnormal prehospital vital signs, and EMS transport interval.

Results

Of 1,180 eligible patients (552 in the pre-implementation period; 628 in the post-implementation period), the mean age was 72 years old, 45% were female, and 25% were minority race-ethnicity. Median (interquartile range) fluid volume (in mL) increased between the pre- and post-implementation periods (600 [400,1,000] and 850 [500–1,000], respectively). Goal fluid volume was achieved in 70% of pre-implementation patients and 82% of post-implementation patients. In adjusted analysis, post-implementation patients were significantly more likely to receive goal fluid volume than pre-implementation patients (adjusted odds ratio (aOR) 2.00, 95% confidence interval (CI) 1.51–2.66). Pre-post in-hospital mortality was not significantly different (aOR 0.91, 95% CI 0.59–1.39).

Conclusion

In a single EMS system, sepsis education and introduction of a rapid infusion device was associated with achieving goal fluid volume for suspected sepsis. Further research is needed to assess the clinical effectiveness of infusion device implementation to improve sepsis patient outcomes.

Disclosure Statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

This work was supported by Emergency Medicine Foundation 410 Medical LifeFlow® Resuscitation Research Grant.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 85.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.