The effect of the tongue and groove of the multileaf collimator on dose distribution: examination of results of measurements and treatment planning system

ORCID Icon
Pages 1404-1412 | Received 06 Jun 2023, Accepted 26 Aug 2023, Published online: 31 Aug 2023

References

  • Hernandez, V.; Angerud, A.; Bogaert, E. Challenges in modeling the agility multileaf collimator in treatment planning systems and current needs for improvement. Med. Phys. 2022, 1–13.
  • Kung, J.; Chen, G. Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy. Med. Phys. 2000, 27 (7), 1617–1622.
  • Williams, M.; Metcalfe, P. Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system. Phys. Med. Biol. 2006, 51 (4), N65.
  • Li, J.S.; Lin, T.; Chen, L.; Price Jr, R.A.; Ma, C.M. Uncertainties in IMRT dosimetry. Med. Phys. 2010, 37 (6) Part1), 2491–2500.
  • Mans, A.; Schuring, D.; Arends, M.P., et al. The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy. Phys. Med. Biol. 2016, 61 (19), 7221.
  • Haryanto, F.; Fippel, M.; Bakai, A.; Nüsslin, F. Study on the tongue and groove effect of the Elekta multileaf collimator using Monte Carlo simulation and film dosimetry. Strahlenther Onkol 2004, 180, 57–61.
  • Webb, S. Intensity-modulated radiation therapy: dynamic MLC (DMLC) therapy, multisegment therapy and tomotherapy. An example of QA in DMLC therapy. Strahlenther Onkol 1998, 174 (Suppl 2), 8–12.
  • Que, W.; Kung, J.; Dai, J.  Tongue-and-groove’ effect in intensity modulated radiotherapy with static multileaf collimator fields. Phys. Med. Biol. 2004, 49, 399–405.
  • Huq, M.S.; Das, I.J.; Steinberg, T.; Galvin, J.M. A dosimetric comparison of various multileaf collimators. Phys. Med. Biol. 2002, 47, N159–N170.
  • Deng, J.; Pawlicki, T.; Chen, Y.; Li, J.S.; Jiang, S.B.; Ma, C.M. The MLC tongue-and groove effect on IMRT dose distributions. Phys. Med. Biol. 2001, 46, 1039–1060.
  • Agazaryan, N.; Solberg, T.D. Segmental and dynamic intensity modulated radiotherapy delivery techniques for micro-multileaf collimator. Med. Phys. 2003, 30, 1758–1767.
  • Galvin, J.M.; Smith, A.R.; Lally, B. Characterization of a multi-leaf collimator system. Int. J. Radiat. Oncol. Biol. Phys. 1993, 25, 181–192.
  • Chui, C.S.; LoSasso, T.; Spirou, S. Dose calculations for photon beams with intensity modulation generated by dynamic jaw or multileaf collimators. Med. Phys. 1994, 21, 1237–1243.
  • Wang, X.; Spirou, S.; LoSasso, T.; Stein, J.; Chui, C.; Mohan, R. Dosimetric verification of intensity modulated fields. Med. Phys. 1996, 23, 317–328.
  • Kim, H.J.; Kim, S.; Park, Y.K.; Kim, J.; Park, J.M.; Ye, S.J. Multileaf collimator tongue-and groove effect on depth and off-axis doses: a comparison of treatment planning data with measurements and Monte Carlo calculations. Med. Dosimetry 2015, 40, 271–278.
  • Deng, J.; Pawlicki, T.; Chen, Y.; Li, J.; Jiang, S.B.; Ma, C.M. The MLC tongue-and-groove effect on IMRT dose distributions. Phys. Med. Biol. 2001, 46, 1039–1060.
  • Webb, S.; Bortfeld, T.; Stein, J.; Convery, D. The effect of stair-step leaf transmission on the ‘tongue-and-groove problem’ in dynamic radiotherapy with a multileaf collimator. Phys. Med. Biol. 1997, 42, 595–602.
  • Siochi, R.A.C. Minimizing static intensity modulation delivery time using an intensity solid paradigm. Int. J. Radiat. Oncol. Biol. Phys. 1999, 43, 671–680.
  • Van Santvoort, J.P.C.; Heijmen, B.J.M. Dynamic multileaf collimator without “tongue and groove effects. Phys. Med. Biol. 1996, 41, 2091–2105.
  • Bortfeld, T.; Kahler, D.L.; Waldron, T.J.; Boyer, A.L. X-ray field compensation with multileaf collimators. Int. J. Radiat. Oncol. Biol. Phys. 1994, 28, 723–730.
  • Xia, P.; Verhey, L. Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments. Med. Phys. 1998, 25, 1424–1434.
  • Saez, J.; Hernandez, V.; Goossens, J.; De Kerf, G.; Verellen, D. A novel procedure for determining the optimal MLC configuration parameters in treatment planning systems based on measurements with a Farmer chamber. Phys. Med. Biol. 2020, 65, 155006.
  • RaySearch Laboratories. RayStation 9B reference manual, 2019.
  • PTW The Dosimetry Company. PTW products for medical physics in radiation therapy, 2022.
  • Low, D.A.; Moran, J.M.; Dempsey, J.F., et al. Dosimetry tools and techniques for IMRT. Med. Phys. 2011, 38, 1313–1138.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.