188
Views
1
CrossRef citations to date
0
Altmetric
ORIGINAL RESEARCH

Accuracy of Traditional and Modern Formulas for Intraocular Lens Power Calculation After Radial Keratotomy Using Standard Keratometry

ORCID Icon, ORCID Icon &
Pages 2589-2597 | Received 21 Jun 2023, Accepted 25 Aug 2023, Published online: 31 Aug 2023

References

  • Feiz V. Intraocular lens power calculation after corneal refractive surgery. Middle East Afr J Ophthalmol. 2010;17(1):63–68. doi:10.4103/0974-9233.61219
  • Koch DD, Liu JF, Emery JM, Hyde LL, Rock RL. Refractive complications of cataract surgery after radial keratotomy. Am J Ophthalmol. 1989;108(6):676–682. doi:10.1016/0002-9394(89)90860-X
  • Awwad ST, Dwarakanathan S, Bowman RW, et al. Intraocular lens power calculation after radial keratotomy: estimating the refractive corneal power. J Cataract Refract Surg. 2007;33(6):1045–1050. doi:10.1016/j.jcrs.2007.03.018
  • Wang L, Koch DD. Intraocular lens power calculations in eyes with previous corneal refractive surgery: challenges, approaches, and outcomes. Taiwan J Ophthalmol. 2021;12(1):22–31. doi:10.4103/tjo.tjo_38_21
  • Kwitko S, Gritz DC, Garbus JJ, Gauderman WJ, McDonnell PJ. Diurnal variation of corneal topography after radial keratotomy. Arch Ophthalmol. 1992;110:351–356. doi:10.1001/archopht.1992.01080150049026
  • Chhadva P, Cabot F, Galor A, Yoo SH. Long-term outcomes of radial keratotomy, laser in situ keratomileusis, and astigmatic keratotomy performed consecutively over a period of 21 years. Case Rep Ophthalmol Med. 2015;2015:592495. doi:10.1155/2015/592495
  • Bardocci A, Lofoco G. Corneal topography and postoperative refraction after cataract phacoemulsification following radial keratotomy. Ophthalmic Surg Lasers. 1999;30:155–159.
  • Kasyanov AA, Ryzhkova EG. IOL power calculation features after radial keratotomy. Ophthalmol Russ. 2022;19(2):325–333. doi:10.18008/1816-5095-2022-2-325-333
  • Xia T, Martinez CE, Tsai LM. Update on intraocular lens formulas and calculations. Asia Pacific J Ophthalmol. 2020;9(3):186. doi:10.1097/APO.0000000000000293
  • Helaly HA, El-Hifnawy MA, Shaheen MS, Abou El-Kheir AF. Accuracy of corneal power measurements for intraocular lens power calculation after myopic laser in situ keratomileusis. Middle East Afr J Ophthalmol. 2016;23(1):122. doi:10.4103/0974-9233.171755
  • Soare C, Patel DS, Ionides A. Cataract surgery outcomes in eyes with previous radial keratotomy. Eye. 2022;36(9):1804–1809. doi:10.1038/s41433-021-01716-6
  • Geggel HS. Intraocular lens power selection after radial keratotomy: topography, manual, and IOLMaster keratometry results using Haigis formulas. Ophthalmology. 2015;122(5):897–902. doi:10.1016/j.ophtha.2014.12.002
  • Aramberri J. Intraocular lens power calculation after corneal refractive surgery: double-K method. J Cataract Refract Surg. 2003;29(11):2063–2068. doi:10.1016/S0886-3350(03)00957-X
  • El-Hifnawy MAM, Shaheen MS, El-Kheir AFA, Hasan IM, Helaly HA. Accuracy of corneal power measurements for intraocular lens power calculation after radial keratotomy. Delta J Ophthalmol. 2011;12(2):126–133.
  • Kane JX, Van Herdeen A, Atik A, Petsoglou C. Intraocular lens power formula accuracy: comparison of 7 formulas. J Cataract Refract Surg. 2016;42:1490–1500. doi:10.1016/j.jcrs.2016.07.021
  • Debellemanière G, Dubois M, Gauvin M, et al. The PEARL-DGS formula: the development of an open source machine learning-based thick IOL calculation formula. Am J Ophthalmol. 2021;232:58–69. doi:10.1016/j.ajo.2021.05.004
  • Shammas HJ, Shammas MC. No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis. J Cataract Refract Surg. 2007;33(1):31–36. doi:10.1016/j.jcrs.2006.08.045
  • Darcy K, Gunn D, Tavassoli S, Sparrow J, Kane JX. Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service. J Cataract Refract Surg. 2020;46(1):2–7.
  • Ma JX, Tang M, Wang L, Weikert MP, Huang D, Koch DD. Comparison of newer IOL power calculation methods for eyes with previous radial keratotomy. Invest Ophthalmol Vis Sci. 2016;57(9):OCT162–8. doi:10.1167/iovs.15-18948
  • Li M, Wang JD, Zhang JS, Mao YY, Cao K, Wan XH. Comparison of the accuracy of three intraocular lens power calculation formulas in cataract patients with prior radial keratotomy. Eur J Med Res. 2023;28(1):20. doi:10.1186/s40001-023-00998-8
  • Curado SX, Hida WT, Vilar CM, Ordones VL, Chaves MA, Tzelikis PF. Intraoperative aberrometry versus preoperative biometry for IOL power selection after radial keratotomy: a prospective study. J Refr Surg. 2019;35(10):656–661. doi:10.3928/1081597X-20190913-01
  • Turnbull AM, Crawford GJ, Barrett GD. Methods for intraocular lens power calculation in cataract surgery after radial keratotomy. Ophthalmology. 2020;127(1):45–51. doi:10.1016/j.ophtha.2019.08.019
  • Dawson VJ, Patnaik JL, Ifantides C, Miller DC, Lynch AM, Christopher KL. Comparison of refractive prediction for intraoperative aberrometry and Barrett True-K no history formula in cataract surgery patients with prior radial keratotomy. Acta Ophthalmol. 2021;99(6):e844–51. doi:10.1111/aos.14688
  • Leite de Pinho Tavares R, de Almeida Ferreira G, Ghanem VC, Ghanem RC. IOL power calculation after radial keratotomy using the haigis and Barrett True-K formulas. J Refr Surg. 2020;36(12):832–837. doi:10.3928/1081597X-20200930-02