163
Views
0
CrossRef citations to date
0
Altmetric
ORIGINAL RESEARCH

Face and Content Validity of an Artificial Eye Model for Secondary Intraocular Lens Fixation via Yamane Technique

, , , , , , & show all
Pages 2063-2069 | Received 01 May 2023, Accepted 10 Jul 2023, Published online: 21 Jul 2023

References

  • Vounotrypidis E, Schuster I, Mackert MJ, Kook D, Priglinger S, Wolf A. Secondary intraocular lens implantation: a large retrospective analysis. Graefes Arch Clin Exp Ophthalmol. 2019;257(1):125–134. doi:10.1007/s00417-018-4178-3
  • Hara T, Hara T. Ten-year results of anterior chamber fixation of the posterior chamber intraocular lens. Arch Ophthalmol. 2004;122(8):1112–1116. doi:10.1001/archopht.122.8.1112
  • Hennig A, Johnson GJ, Evans JR, et al. Long term clinical outcome of a randomised controlled trial of anterior chamber lenses after high volume intracapsular cataract surgery. The Br J Ophthalmol. 2001;85(1):11–17. doi:10.1136/bjo.85.1.11
  • Sawada T, Kimura W, Kimura T, et al. Long-term follow-up of primary anterior chamber intraocular lens implantation. J Cataract Refract Surg. 1998;24(11):1515–1520. doi:10.1016/S0886-3350(98)80176-4
  • Vote BJ, Tranos P, Bunce C, Charteris DG, Da Cruz L. Long- term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation. Am J Ophthalmol. 2006;141(2):308–312. doi:10.1016/j.ajo.2005.09.012
  • Bading G, Hillenkamp J, Sachs HG, Gabel VP, Framme C. Long-term safety and functional outcome of combined pars plana vitrectomy and scleral-fixated sutured posterior chamber lens implantation. Am J Ophthalmol. 2007;144(3):371–377. doi:10.1016/j.ajo.2007.05.014
  • Tamburrelli C, Tamburrelli AC. Sutureless scleral fixated IOL: the “Catcher Pole” technique. Clin Ophthamol. 2021;15:121–128. doi:10.2147/OPTH.S288769
  • Colantuono D, Seknazi D, Miere A, Amoroso F, Glacet-Bernard A, Souied EH. Sutureless intrascleral fixation using a uniquely designed intraocular lens. J Fr Ophthalmol. 2021;44(7):957–961. doi:10.1016/j.jfo.2020.10.025
  • Gabor S, Pavlidis M. Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2007;33(11):1851–1854. doi:10.1016/j.jcrs.2007.07.013
  • Yamane S, Sato S, Maruyama-Inoue M, Kadonosono K. Flanged intrascleral intraocular lens fixation with double-needle technique. Ophthalmol. 2017;124(8):1136–1142. doi:10.1016/j.ophtha.2017.03.036
  • Li X, Ni S, Li S, et al. Comparison of three intraocular lens implantation procedures for aphakic eyes with insufficient capsular support: a network meta-analysis. Am J Ophthalmol. 2018;192:10–19. doi:10.1016/j.ajo.2018.04.023
  • Yalcinbayir O, Avci R, Ucan Gunduz G, Mavi Yildiz A, Cetin Efe A, Baykara M. Comparison of two techniques in posterior lens dislocations: scleral suture fixation vs. modified Yamane intrascleral lens fixation. J Fr Ophthalmol. 2022;45(1):13–19. doi:10.1016/j.jfo.2021.09.009
  • Kelkar A, Kelkar J, Kothari A, et al. Comparison of two modified sutureless techniques of scleral fixation of intraocular lens. Ophthalmic Surg Lasers Imaging Retina. 2018;49:e129–e134.
  • Wong HM, Kam KW, Rapuano CJ, Young AL. A systematic review on three major types of scleral-fixated intraocular lens implantation. Asia Pac J Ophthalmol. 2021;10(4):388–396. doi:10.1097/APO.0000000000000369
  • Gelman RA, Garg S. Novel Yamane technique modification for haptic exposure after glued intrascleral haptic fixation. Am J Ophthalmol Case Rep. 2019;14:101–104. doi:10.1016/j.ajoc.2019.03.009
  • Yiasemidou M, Gkaragkani E, Glassman D, Biyani CS. Cadaveric simulation: a review of reviews. Ir J Med Sci. 2018;187(3):827–833. doi:10.1007/s11845-017-1704-y
  • Swift A, Gooi P. Artificial eye models: an opportunity to increase surgical training exposure in ophthalmology during and beyond the COVID-19 pandemic. J Clin Ophthalmol. 2020;4:16–18.
  • Gorner A, Waldner D, Swift A, Docherty G, Schlenker M, Gooi P. Face and content validity of a synthetic eye model for Ab-interno goniotomy and canaloplasty. Clin Res Ophthalmol. 2020;3(1):1–7.
  • Waldner D, Gorner A, Swift A, Ahmed Y, Chung H, Gooi P. Face and content validity of the SimulEYE A-Vit model for anterior vitrectomy. Can J Ophthalmol. 2020;55(5):458–460. doi:10.1016/j.jcjo.2020.04.006
  • Loewen D, Al-Ani A, Penny M, Swift A, Gorner A, Gooi P. Face and content validity of an artificial eye model for secondary IOL fixation. Arch Ophthalmol Opto. 2021;4(1):1–7. doi:10.22259/2638-5120.0401001
  • McDougall EM. Validation of surgical simulators. J Endourol. 2007;21(3):244–247. doi:10.1089/end.2007.9985
  • Human Tissue Banking in Canada: costing and economic analysis - final report. Ottawa; 2003. Available from: https://profedu.blood.ca/sites/msi/files/Human-Tissue-Banking.pdf. Accessed July 17, 2023.
  • Accreditation Council for Graduate Medical Education. ACGME program requirements for graduate medical education in ophthalmology; 2022.
  • Wentzell DD, Chung H, Hanson C, Gooi P. Competency-based medical education in ophthalmology residency training: a review. Can J Ophthalmol. 2020;55:12–19. doi:10.1016/j.jcjo.2019.07.004
  • Lee GA, Chiang MY, Shah P. Pig eye trabeculectomy – a wet lab teaching model. Eye. 2006;20:32–37. doi:10.1038/sj.eye.6701784
  • Ang JL, Collis SA, Dhillon B, Cackett P. The eye in forensic medicine: a narrative review. Asia Pac J Ophthalmol. 2021;10:486–494.
  • Kawashima W, Hatake K, Kudo R, et al. Estimating the time of death on the basis of corneal opacity. J Forensic Res. 2015;6(1):e1000269.
  • Tsunenari S, Kanda M. The post-mortem changes of corneal turbidity and its water content. Med Sci Law. 1977;17(2):108–111. doi:10.1177/002580247701700208