234
Views
0
CrossRef citations to date
0
Altmetric
ORIGINAL RESEARCH

Optical-Quality Analysis and Defocus-Curve Simulations of a Novel Hydrophobic Trifocal Intraocular Lens

, , ORCID Icon & ORCID Icon
Pages 3915-3923 | Received 18 Oct 2023, Accepted 20 Nov 2023, Published online: 17 Dec 2023

References

  • de Silva SR, Evans JR, Kirthi V, Ziaei M, Leyland M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2016;12(12):CD003169. doi:10.1002/14651858.CD003169.pub4
  • Alio JL, Plaza-Puche AB, Fernandez-Buenaga R, Pikkel J, Maldonado M. Multifocal intraocular lenses: an overview. Surv Ophthalmol. 2017;62(5):611–634. doi:10.1016/j.survophthal.2017.03.005
  • Ang R. Long-term trifocal toric intraocular lens outcomes in Asian eyes after cataract surgery. J Cataract Refract Surg. 2023;49(8):832–839. doi:10.1097/j.jcrs.0000000000001195
  • Lubiński W, Podborączyńska-Jodko K, Kirkiewicz M, Mularczyk M, Post M. Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses. Int Ophthalmol. 2020;40(10):2553–2562. doi:10.1007/s10792-020-01435-z
  • Niazi S, Gatzioufas Z, Dhubhghaill SN, et al. Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs. Adv Ther. 2023. doi:10.1007/s12325-023-02698-5
  • Breyer DRH, Beckers L, Ax T, Kaymak H, Klabe K, Kretz FTA. Aktuelle Übersicht: multifokale Linsen und Extended-Depth-of-Focus-Intraokularlinsen [Current Review: multifocal Intraocular Lenses and Extended Depth of Focus Intraocular Lenses]. KlinMonbl Augenheilkd. 2020;237(8):943–957. doi:10.1055/a-1111-9380
  • Karam M, Alkhowaiter N, Alkhabbaz A, et al. Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: an Updated Systematic Review and Meta-Analysis. Am J Ophthalmol. 2023;251:52–70. doi:10.1016/j.ajo.2023.01.024
  • A RET. Long Term Clinical Outcomes of Hydrophilic and Hydrophobic Versions of a Trifocal IOL with the Same Optical Design. Clin Ophthalmol. 2023;17:623–632. doi:10.2147/OPTH.S403351
  • Borkenstein AF, Borkenstein EM. Clinical Performance of New Enhanced Monofocal Intraocular Lenses: comparison of Hydrophobic C-loop and Hydrophilic Plate-Haptic Platform. Adv Ther. 2023;40(10):4561–4573. doi:10.1007/s12325-023-02635-6
  • Janardhanan R, Garg P, Ranjan Srivastava M, Kumari R. Intra Ocular Lens Technology - A Review of Journey from Its Inception. Ophthalmol Res Int J. 2020;11(3):1–9.
  • Łabuz G, Papadatou E, Khoramnia R, Auffarth GU. Longitudinal Chromatic Aberration and Polychromatic Image Quality Metrics of Intraocular Lenses. J Refract Surg. 2018;34(12):832–838. doi:10.3928/1081597X-20181108-01
  • English D. ISO-11979-2. Ophthalmic implants — intraocular lenses — part 2: optical properties and test methods. Int Organization Standardization. 2014.
  • Bass M, DeCusatis C, Enoch J. Handbook of Optics, Volume II: Design, Fabrication and Testing, Sources and Detectors, Radiometry and Photometry. McGraw-Hill, Inc; 2009.
  • Alarcon A, Canovas C, Rosen R, et al. Preclinical metrics to predict through-focus visual acuity for pseudophakic patients. Biomed Opt Express. 2016;7(5):1877–1888. doi:10.1364/BOE.7.001877
  • Alba-Bueno F, Garzon N, Vega F, Poyales F, Millan MS. Patient-Perceived and Laboratory-Measured Halos Associated with Diffractive Bifocal and Trifocal Intraocular Lenses. Curr Eye Res. 2018;43(1):35–42. doi:10.1080/02713683.2017.1379541
  • Carson D, Xu Z, Alexander E, Choi M, Zhao Z, Hong X. Optical bench performance of 3 trifocal intraocular lenses. J Cataract Refract Surg. 2016;42(9):1361–1367. doi:10.1016/j.jcrs.2016.06.036
  • Yan W, Łabuz G, Khoramnia R, Auffarth GU. Trifocal Intraocular Lens Selection: predicting Visual Function From Optical Quality Measurements. J Refract Surg. 2023;39(2):111–118. doi:10.3928/1081597X-20221207-02
  • Khoramnia R, Kretz F, Gerl M, Breyer D, Auffarth GU. Long-term Clinical Outcomes After Bilateral Implantation of Two Trifocal Diffractive IOLs. J Refract Surg. 2023;39(12):798–807. doi:10.3928/1081597X-20231006-01
  • Torky MA, Nokrashy AE, Metwally H, Abdelhameed AG. Visual performance following implantation of presbyopia correcting intraocular lenses. Eye. 2022;1–9.
  • Zhu M, Fan W, Zhang G. Visual outcomes and subjective experience with three intraocular lenses based presbyopia correcting strategies in cataract patients. Sci Rep. 2022;12(1):19625. doi:10.1038/s41598-022-23694-9
  • Łabuz G, Yan W, Baur ID, Khoramnia R, Auffarth GU. Comparison of Five Presbyopia-Correcting Intraocular Lenses: optical-Bench Assessment with Visual-Quality Simulation. J Clin Med. 2023;12(7):2523. doi:10.3390/jcm12072523
  • Łabuz G, van den Berg TJTP, Auffarth GU, Khoramnia R. Light scattering from a diffractive-refractive intraocular lens: a goniometer-based approach for individual zone assessment. Biomed Opt Express. 2022;13(12):6724–6732. doi:10.1364/BOE.474778
  • Vega F, Alba-Bueno F, Millán MS, Varón C, Gil MA, Buil JA. Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses. Invest Ophthalmol Vis Sci. 2015;56(6):3967–3975. doi:10.1167/iovs.15-16600
  • Vargas V, Alio JL, Oliveira RF, Renna A, Yebana P. Long-term objective and subjective outcomes following bilateral implantation of diffractive bifocal or trifocal intraocular lenses. Eur J Ophthalmol. 2021;31(3):1014–1020. doi:10.1177/1120672120926870
  • Piñero DP, Maldonado-López MJ, Molina-Martin A, et al. Randomised placebo-controlled clinical trial evaluating the impact of a new visual rehabilitation program on neuroadaptation in patients implanted with trifocal intraocular lenses. Int Ophthalmol. 2023;43(11):4035–4053. doi:10.1007/s10792-023-02809-9
  • Sezgin Asena B. Visual and refractive outcomes, spectacle Independence, and visual disturbances after cataract or refractive lens exchange surgery: comparison of 2 trifocal intraocular lenses. J Cataract Refract Surg. 2019;45(11):1539–1546. doi:10.1016/j.jcrs.2019.06.005
  • Law EM, Aggarwal RK, Kasaby H. Clinical Outcomes with a New Trifocal Intraocular Lens. Eur J Ophthalmol. 2013;24(4):501–508. doi:10.5301/ejo.5000407
  • Rampat R, Gatinel D. Multifocal and Extended Depth-of-Focus Intraocular Lenses in 2020. Ophthalmology. 2021;128(11):e164–e185. doi:10.1016/j.ophtha.2020.09.026