65
Views
0
CrossRef citations to date
0
Altmetric
ORIGINAL RESEARCH

Comparison of the Residual Amount of an Ophthalmic Viscosurgical Device Among Different Types of Intraocular Lens Implants in vitro

ORCID Icon, , , & ORCID Icon
Pages 1083-1091 | Received 14 Feb 2024, Accepted 17 Apr 2024, Published online: 20 Apr 2024

References

  • Arshinoff SA, Jafari M. New classification of ophthalmic viscosurgical devices--2005. J Cataract Refract Surg. 2005;31:2167–2171. doi:10.1016/j.jcrs.2005.08.056
  • Higashide T, Sugiyama K. Use of viscoelastic substance in ophthalmic surgery - focus on sodium hyaluronate. Clin Ophthalmol. 2008;2:21–30.
  • Gerberich AJ, Ipema HJ. A primer on ocular viscosurgical devices. Am J Health Syst Pharm. 2021;78:2020–2032.
  • Steiner RF. Ophthalmic viscosurgical devices: physical characteristics, clinical applications, and complications. In: Cataract Surgery. 3rd ed. Saunders Elsevier; 2010.
  • Sholohov G, Levartovsky S. Retained ophthalmic viscosurgical device material in the capsular bag 6 months after phacoemulsification. J Cataract Refract Surg. 2005;31:627–629.
  • Miller KM, Oetting TA, Tweeten JP, et al. Cataract in the adult eye preferred practice pattern. Ophthalmology. 2022;129:P1–P126.
  • Mamalis N, Edelhauser HF, Dawson DG, Chew J, LeBoyer RM, Werner L. Toxic anterior segment syndrome. J Cataract Refract Surg. 2006;32:324–333.
  • Durand ML. Endophthalmitis. Clin Microbiol Infect. 2013;19:227–234.
  • Shimada H, Arai S, Nakashizuka H, Hattori T, Yuzawa M. Reduction of anterior chamber contamination rate after cataract surgery by intraoperative surface irrigation with 0.25% povidone-iodine. Am J Ophthalmol. 2011;151:11–17.e1.
  • Oshika T, Ohashi Y. Endophthalmitis after cataract surgery: effect of behind-The-lens washout. J Cataract Refract Surg. 2017;43:1399–1405. doi:10.1016/j.jcrs.2017.08.009
  • Auffarth GU, Holzer MP, Vissesook N, Apple DJ, Völcker HE. Removal times and techniques of a viscoadaptive ophthalmic viscosurgical device. J Cataract Refract Surg. 2004;30:879–883. doi:10.1016/j.jcrs.2003.08.031
  • Auffarth GU, Holzer MP, Visessook N, Apple DJ, Völcker HE. Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intraocular lens material. J Cataract Refract Surg. 2004;30:2410–2414. doi:10.1016/j.jcrs.2004.03.039
  • Assia EI, Apple DJ, Lim ES, Morgan RC, Tsai JC. Removal of viscoelastic materials after experimental cataract surgery in vitro. J Cataract Refract Surg. 1992;18:3–6. doi:10.1016/S0886-3350(13)80376-8
  • Bissen-Miyajima H. In vitro behavior of ophthalmic viscosurgical devices during phacoemulsification. J Cataract Refract Surg. 2006;32:1026–1031. doi:10.1016/j.jcrs.2006.02.039
  • Oshika T, Okamoto F, Kaji Y, et al. Retention and removal of a new viscous dispersive ophthalmic viscosurgical device during cataract surgery in animal eyes. Br J Ophthalmol. 2006;90:485–487. doi:10.1136/bjo.2005.085969
  • Gunji H, Ohki T. Quantification of residual ophthalmic viscosurgical device after irrigation/aspiration in experimental cataract surgery in vitro. J Cataract Refract Surg. 2019;45:1324–1329. doi:10.1016/j.jcrs.2019.03.025
  • Mitani A, Suzuki T, Tasaka Y, et al. Evaluation of a new method of irrigation and aspiration for removal of ophthalmic viscoelastic device during cataract surgery in a porcine model. BMC Ophthalmol. 2014;14:129.
  • Pereira FA, Werner L, Milverton EJ, Coroneo MT. Miyake-Apple posterior video analysis/photographic technique. J Cataract Refract Surg. 2009;35:577–587.
  • Abouali O, Bayatpour D, Ghaffariyeh A, Ahmadi G. Simulation of flow field during irrigation/aspiration in phacoemulsification using computational fluid dynamics. J Cataract Refract Surg. 2011;37:1530–1538.
  • Kaji Y, Yamashita M, Sakakibara J, Oshika T. Visualization of irrigation fluid flow and calculation of its velocity distribution in the anterior chamber by particle image velocimetry. Graefes Arch Clin Exp Ophthalmol. 2012;250:1023–1027.
  • Hyon JY, Yeo HE. Rotational stability of a single-piece hydrophobic acrylic intraocular lens during removal of ophthalmic viscosurgical devices. Am J Ophthalmol. 2010;149:253–257.e1.