405
Views
3
CrossRef citations to date
0
Altmetric
Treatment

Real-life association between inhaler technique, patient preference and asthma control in patients with uncontrolled asthma switched to budesonide/formoterol DuoResp® Spiromax® combination

, md, phd, , md, phd, , msc & , phd
Pages 765-774 | Received 20 May 2020, Accepted 09 Jan 2021, Published online: 13 Feb 2021
 

Abstract

Objective: In asthma, treatment effectiveness is strongly influenced by the quality of inhaler use. New devices such as Spiromax® have been specifically developed to improve ease of use. It is crucial to determine whether switching to such a device improves inhaler technique and clinical outcomes, and to identify factors associated with handling errors.

Methods: This observational study assessed inhaler device handling errors in 1435 asthma patients recruited via 135 participating physicians in France, before and after switching therapy from the Symbicort Turbuhaler® or Seretide® Diskus® to DuoResp® Spiromax®. Patients received training in the use of their new device at baseline and were re-assessed after three months.

Results: After three months of use, 67% of patients were using the DuoResp® Spiromax® with no handling errors, and 88% with no critical errors. The presence of comorbidities was associated with handling errors overall. Concurrent illness potentially affecting device handling and previous training were associated with critical device handling errors. Most patients (85.4%) preferred DuoResp® Spiromax® over their previous device. Levels of inadequately controlled or uncontrolled asthma were reduced from baseline among patients using DuoResp® Spiromax® (8.6% versus 64.6%), and were higher in patients with critical handling errors.

Conclusions: Effective patient education, correct inhaler technique, treatment adherence and devices associated with high patient satisfaction are interrelated factors key to the successful delivery of inhaled asthma therapy. Inhaler technique and patient device satisfaction should be routinely assessed in treated patients with uncontrolled asthma.

Supplemental data for this article can be accessed at publisher’s website.

Acknowledgements

The authors acknowledge the contributions to the study of Prof. Thomas Similowski (Université Pierre et Marie Curie, Paris, France).

Medical writing support was provided by Ian C. Grieve, PhD, of Ashfield Healthcare Communications, part of UDG Healthcare plc, and was funded by Teva Europe, Amsterdam.

Declaration of interest

Nicolas Roche reports grants and personal fees from Boehringer Ingelheim, Novartis, and personal fees from Teva, GSK, AstraZeneca, Chiesi, Mundipharma, Cipla, Sanofi, Sandoz, 3 M, Pfizer, and Zambon outside of the published work. Bernard Aguilaniu reports grants from Boehringer Ingelheim, Novartis, GSK, AstraZeneca, Chiesi, and personal fees from Boehringer Ingelheim, GSK, Chiesi outside of the published work. Simon Paternotte declares no conflicts of interest. Nathalie Dallery is an employee of Teva Santé.

Data availability

Data are available upon reasonable request; please contact [email protected] with any enquiries regarding data access.

This study was sponsored by Teva Santé, France. Medical writing support was funded by Teva Pharmaceuticals Europe.

Log in via your institution

Log in to Taylor & Francis Online

PDF download + Online access

  • 48 hours access to article PDF & online version
  • Article PDF can be downloaded
  • Article PDF can be printed
USD 65.00 Add to cart

Issue Purchase

  • 30 days online access to complete issue
  • Article PDFs can be downloaded
  • Article PDFs can be printed
USD 1,078.00 Add to cart

* Local tax will be added as applicable

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.