322
Views
0
CrossRef citations to date
0
Altmetric
Urogenital Radiology

Diffusion tensor MRI of the kidney at 3.0 and 1.5 Tesla

, , , , , , , , , , , & show all
Pages 1059-1063 | Accepted 21 Jun 2010, Published online: 25 Aug 2010
 

Abstract

Background: Diffusion tensor imaging (DTI) at 3 T provides information on the microstructure and pathophysiology of tissues that is not available from conventional imaging with an advantage of high signal to noise ratio (SNR).

Purpose: To evaluate the feasibility of DTI of the normal kidney at 3.0 T compared to results obtained at 1.5 T.

Material and Methods: DTI of the normal kidney of 15 healthy volunteers obtained with 3.0 and 1.5 T scanners using respiration-triggered acquisition was examined. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of both the renal cortex and the medulla and SNRs were measured (b-values 0 and 400 s/mm2, diffusion direction of 6). The image quality of FA and ADC maps was also compared subjectively.

Results: The FA values of the renal cortex were 0.15 ± 0.03 at 3.0 T and 0.14± 0.03 at 1.5 T on average. This difference was not significant. The FA values of the renal medulla were 0.49 ±0.04 at 3.0 T and 0.42 ± 0.05 at 1.5 T. ADC values of the renal cortex were 2.46 × 10−3± 0.09 mm2/s at 3.0 T and 2.20 ×10−3±0.11 mm2/s at 1.5 T. The ADC values of the renal medulla were 2.08 × 10−3 ± 0.08 mm2/s at 3.0 T and 1.90 × 10−3± 0.11 mm2/s at 1.5 T. These FA and ADC values were consistent with previous publications. The difference was significant for the FA value of the medulla (P< 0.01) and ADC values in both cortex and medulla (P < 0.01). The subjective image quality of the FA map with the 3.0 T scanner was significantly superior to that with the 1.5 T scanner (P< 0.01), but not significant for the ADC map (P = 0.18). There was a significant difference in SNR between 3.0 T (48.8 ± 6.6) and 1.5 T images (32.8 ± 5.0).

Conclusion: The feasibility of renal DTI with a 3.0 T magnet resulting in improved SNR was demonstrated.

Acknowledgement

This study was supported by grand-in-aid no. 16209035 from the Ministry of Education, Culture, Sports, Science and Technology.

Declaration of interest: The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Log in via your institution

Log in to Taylor & Francis Online

There are no offers available at the current time.

Related Research

People also read lists articles that other readers of this article have read.

Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.

Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.