References
- Safety Analysis Report for Packaging Model 9977 Type B(M)F-96, Rev. 2, S-SARP-G-00001; 2007, Washington Savannah River Company, (WSRC).
- Safety Analysis Report for Packaging Model 9977, Addendum 7: Justification for Dual 3013 Contents, S-SARA-G-00012, Revision 3; July 2012, Savannah River National Laboratory (SRNL).
- Safety Evaluation Report for the Justification for Duel-3013 Contents, Addendum 7 to Safety Analysis Report for Packaging Model 9977, Docket Number: 11-41-9977, SER Rev. 12, DOE CoC; 2012.
- US NRC Regulations Title 10, Code of Federal Regulations, Part 71.43g (10 CFR 71), Packaging and Transportation of Radioactive Material; August, 2013.
- Modeling thermal contact, in ANSYS Contact Technology Guide, version 10, Page 6-1; 2005.
- Yamada K., Kurosaki K., Uno M. and Yamanaka S.: ‘Evaluation of thermal properties of mixed oxide fuel by molecular dynamics’, J. Alloys Compd, 2000, 307, 1–9.
- Tsai H., Liu Y. Y., Gupta N. K., Smith A. C., Potential eutectic failure mechanism for stainless steel 3013 cans containing plutonium metal not analyzed in the safety basis. RAMPAC webpage http://rampac.energy.gov/docs/whitepapers/Pu-Fe_eutectic.pdf; Nov. 2006.
- Daugherty W. L., Eighth Interim Status Report: Model 9975 PCV O-ring Fixture Long-Term Leak Performance (U), SRNL-TR-2013-00151, Savannah River National Laboratory.
- American National Standard for Radioactive Materials, Leakage Test on Packages for Shipment, American National Standards Institute (ANSI), N14.5; 1997.
- Celina M., Gillen K. T. and Assink R. A.: ‘Accelerated aging and lifetime prediction: review of non-Arrhenius behavior due to two competing processes’, Polym. Degrad. Stab., 2005, 90, 395.
- Gillen K. T., Bernstein R. and Derzon D. K.: ‘Evidence of non-Arrhenius behavior from laboratory aging and 24-year field aging of polychloroprene rubber materials’, Polym. Degrad. Stab., 2005, 87, 57.
- Han Z.G., Shah, V. N. and Liu Y. Y, “Extending Periodic Leakage Rate Testing of 9977 Packages with Elastomeric O-rings”, Proc. ASME 2014 Pressure Vessels and Piping Conference, PVP 2014, July 20–24, 2014, Anaheim, CA.
- Safety Analysis Report for Packaging Model 9977, Addendum 4: Justification for Use of RFID System and Extension of Packaging Periodical Maintenance Interval, S-SARA-G00010; January 2011.
- Liu Y, Tsai H. C. and Shuler J.: ‘Extending intervals for periodic leakage rate testing of radioactive material transportation packagings’, Packag. Transp. Storage Secur. Radioact. Mater., 2011, 22, 27.